Buy ABB AX40-30-10-81 3 Pole Contactor, 1SBL321074R8110 Online At Best Price On Moglix
ABB AX40-30-10-81 3 Pole Contactor, 1SBL321074R8110

Hover to Zoom

ABB AX40-30-10-81 3 Pole Contactor, 1SBL321074R8110

Check for price and availability.

Available on Request

Product Specifications

BrandABB
Warranty

1 Year

Part Number

1SBL321074R8110

Terminal Type

Screw Terminals

Dimensions

5.4x9x1.83 cm

Weight

667 g

Operating Time

Between Coil De-Energization & NC Contact Closing: 7-14 ms

Between Coil De-Energization & NO Contact Opening: 4-11 ms

Between Coil Energization & NC Contact Opening: 6-18 ms

Between Coil Energization & NO Contact Closing: 8-21 ms

EAN

3471522401816

Operating Voltage

Auxiliary Circuit: 690 V

Main Circuit: 690 V

Frequency

Auxiliary Circuit: 50-60 Hz

Main Circuit: 50-60 Hz

Number of Poles

3 Pole

Number of Contacts

Main Contacts NC: 3

Main Contacts NO: 0

Auxillary Contact

Auxiliary Contacts NO: 1

Auxiliary Contacts NC: 0

Item Code

AX40-30-10-81

Items in Pack

1 Piece

More From ContactorsVIEW ALL

Moglix Guarantees

  • Genuine Products
  • Secure Payment
  • Easy Returns

Product Information

Browse through the extensive list of Contactors at Moglix. Shop online for other ABB Contactors available at Moglix in the lowest price range.

  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 deg C 65 A
    acc. to IEC 60947-5-1, q = 40 deg C 16 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 40 deg C 60 A
    (690 V) 70 deg C 42 A
    (220 / 240 V) 55 deg C 60 A
  • Rated Operational Current AC-3 (Ie):
    (220 / 230 / 240 V) 55 deg C 40 A
    (380 / 400 V) 55 deg C 40 A
    (415 V) 55 deg C 40 A
    (440 V) 55 deg C 37 A
    (500 V) 55 deg C 33 A
    (690 V) 55 deg C 25 A
  • Rated Operational Power AC-3 (Pe):
    (220 / 230 / 240 V) 11 kW
    (380 / 400 V) 18.5 kW
    (415 V) 18.5 kW
    (440 V) 22 kW
    (500 V) 22 kW
    (690 V) 22 kW
  • Rated Operational Current AC-15 (Ie):
    (220 / 240 V) 4 A
    (24 / 127 V) 6 A
    (400 / 440 V) 2 A
    (500 V) 2 A
    (690 V) 2 A
    (380 / 440 V) 3 A
  • Rated Short-time Withstand Current (Icw):
    at 40 deg C Ambient Temp, in Free Air, from a Cold State 10 s 400 A
    at 40 deg C Ambient Temp, in Free Air, from a Cold State 15 min 65 A
    at 40 deg C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
    at 40 deg C Ambient Temp, in Free Air, from a Cold State 1 s 600 A
    at 40 deg C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
    for 0.1 s 140 A
    for 1 s 100 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
  • Maximum Electrical Switching Frequency:
    AC-1 600 cycles per hour
    AC-15 1200 cycles per hour
    AC-3 1200 cycles per hour
    DC-13 900 cycles per hour
  • Rated Operational Current DC-13 (Ie):
    (110 V) 1.1 A / 121 W
    (220 V) 0.55 A / 121 W
    (400 V) 2.8 A / 134 W
    (500 V) 2 A / 144 W
    (125 V) 1.1 A / 138 W
    (24 V) 6 A / 144 W
    (250 V) 0.55 A / 138 W
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
  • Rated Impulse Withstand Voltage (Uimp):
    6 kV
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Rated Control Circuit Voltage (Uc):
    50 Hz 24 V
    60 Hz 24 V
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20

Environmental

  • Ambient Air Temperature:
    Close to Contactor for Storage -60 ... +80 deg C
    Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 deg C
    Close to Contactor without Thermal O/L Relay -40 ... +70 deg C
    Near Contactor for Operation in Free Air -40 ... +70 deg C
  • Climatic Withstand:
    acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible:
    3000 m
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

  • General Use Rating UL/CSA:
    (600 V AC) 60 A
  • Horsepower Rating UL/CSA:
    (120 V AC) Single Phase 3 Hp
    (240 V AC) Single Phase 7.5 Hp
    (200 ... 208 V AC) Three Phase 10 Hp
    (220 ... 240 V AC) Three Phase 15 Hp
    (440 ... 480 V AC) Three Phase 30 Hp
    (550 ... 600 V AC) Three Phase 40 Hp
  • Tightening Torque UL/CSA:
    Auxiliary Circuit 9 in·lb
    Control Circuit 9 in·lb
    Main Circuit 20 in·lb

Similar Products

Legrand 3 Pole Contactors RTX³ 40 Integrated Auxiliary Contacts 1 NO + 1 NC, 4166 64

38% OFF

₹1,874

₹1,159

  • Brand: Legrand

CUSTOMER REVIEWS

Customer Reviews on ABB AX40-30-10-81 3 Pole Contactor, 1SBL321074R8110

0

There are no customer reviews yet.

Share Your Thoughts With Other Customers

Rate the Product

CUSTOMER QUESTIONS & ANSWERS

Typical questions asked about products:

- Is the item durable?

- Is this item easy to use?

- What are the dimensions of this item?