Key features

  • Rated Insulation Volatge: Acc.to IEC 60947-4-1 & VDE 0110 (Gr. C): 690 V.
  • Rated Impulse Withstand Voltage: 6 KV.
  • Degree of Protection: Acc.to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20.
  • Acc.to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20.
  • Acc.to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20.

Product Specifications

BrandABB
Poles

3 Poles

Warranty

1 Year

Part Number

1SBL921074R8001

Terminal Type

Screw Terminals

Dimensions

4.4x7.4x7.4 cm

Weight

326 g

Ambient Temperature

Close to Contactor for Storage -60 to +80deg C

Close to Contactor Fitted with Thermal O/L Relay -25 to +55deg C

Close to Contactor without Thermal O/L Relay -40 to +70deg C

Near Contactor for Operation in Free Air -40 to +70deg C

Operating Time

Between Coil De-Energization and NC Contact Closing: 9 to 16 ms

Between Coil De-Energization and NO Contact Opening: 4 to 11 ms

Between Coil Energization and NC Contact Opening: 7 to 21 ms

Between Coil Energization and NO Contact Closing: 10 to 26 ms

EAN

3471522396808

Operating Voltage

Auxiliary Circuit: 690 V

Main Circuit: 690 V

Frequency

Auxiliary Circuit: 50 - 60 Hz

Main Circuit: 50 - 60 Hz

Number of Contacts

Main Contacts NO: 3

Main Contacts NC: 0

Auxillary Contact

Auxiliary Contacts NO: 0

Auxiliary Contacts NC: 1

Item Code

AX18-30-01-80

Items in Pack

1 Piece

RETURN POLICY

Upto 7 days
returnable
Wrong
Product
Damaged
Product
Defective
Product
Check delivery and payment options ?

*Shipping charge applicable as per serviceability
* COD payment upto ₹15000
* 7 days free return, Bulk Orders (greater than 10) & heavy items are shipped through surface & may take more than 10 days for delivery.

Check

Shipping charge applicable as per serviceability

Want to buy even more quantity?

View EMI Options *Minimum order placed should be Rs. 3000 across banks while for Bajaj Finserv it should be Rs. 4500
EMIs Available View Plans
On min. purchase of Rs. 3000 across banks and Rs. 4500 for Bajaj Finserv

Product Information

Browse through the extensive list of Contactors at Moglix. Shop online for other ABB Contactors available at Moglix in the lowest price range.

    • Conventional Free-air Thermal Current (Ith):
      acc. to IEC 60947-4-1, Open Contactors q = 40 & 28 A
      acc. to IEC 60947-5-1, q = 40 & 16 A
    • Rated Operational Current AC-1 (Ie):
      (690 V) 40 & 27 A
      (690 V) 70 & 20 A
      (220 / 240 V) 55 & 25 A
    • Rated Operational Current AC-3 (Ie):
      (220 / 230 / 240 V) 55 & 18 A
      (380 / 400 V) 55 & 18 A
      (415 V) 55 & 18 A
      (440 V) 55 & 12 A
      (500 V) 55 & 12 A
      (690 V) 55 & 9 A
    • Rated Operational Power AC-3 (Pe):
      (220 / 230 / 240 V) 4 kW
      (380 / 400 V) 7.5 kW
      (415 V) 9 kW
      (440 V) 5.5 kW
      (500 V) 7.5 kW
      (690 V) 7.5 kW
    • Rated Operational Current AC-15 (Ie):
      (220 / 240 V) 4 A
      (24 / 127 V) 6 A
      (400 / 440 V) 2 A
      (500 V) 2 A
      (690 V) 2 A
      (380 / 440 V) 3 A
    • Rated Short-time Withstand Current (Icw):
      at 40 & Ambient Temp, in Free Air, from a Cold State 10 s 145 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 15 min 28 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 min 60 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 s 300 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 30 s 80 A
      for 0.1 s 140 A
      for 1 s 100 A
    • Maximum Breaking Capacity:
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
    • Maximum Electrical Switching Frequency:
      AC-1 600 cycles per hour
      AC-15 1200 cycles per hour
      AC-3 1200 cycles per hour
      DC-13 900 cycles per hour
    • Rated Operational Current DC-13 (Ie):
      (110 V) 1.1 A / 121 W
      (220 V) 0.55 A / 121 W
      (400 V) 2.8 A / 134 W
      (500 V) 2 A / 144 W
      (125 V) 1.1 A / 138 W
      (24 V) 6 A / 144 W
      (250 V) 0.55 A / 138 W
    • Conventional Free-air Thermal Current (Ith):
      acc. to IEC 60947-4-1, Open Contactors q = 40 & 28 A
      acc. to IEC 60947-5-1, q = 40 & 16 A
    • Rated Operational Current AC-1 (Ie):
      (690 V) 40 & 27 A
      (690 V) 70 & 20 A
      (220 / 240 V) 55 & 25 A
    • Rated Operational Current AC-3 (Ie):
      (220 / 230 / 240 V) 55 & 18 A
      (380 / 400 V) 55 & 18 A
      (415 V) 55 & 18 A
      (440 V) 55 & 12 A
      (500 V) 55 & 12 A
      (690 V) 55 & 9 A
    • Rated Operational Power AC-3 (Pe):
      (220 / 230 / 240 V) 4 kW
      (380 / 400 V) 7.5 kW
      (415 V) 9 kW
      (440 V) 5.5 kW
      (500 V) 7.5 kW
      (690 V) 7.5 kW
    • Rated Operational Current AC-15 (Ie):
      (220 / 240 V) 4 A
      (24 / 127 V) 6 A
      (400 / 440 V) 2 A
      (500 V) 2 A
      (690 V) 2 A
      (380 / 440 V) 3 A
    • Rated Short-time Withstand Current (Icw):
      at 40 & Ambient Temp, in Free Air, from a Cold State 10 s 145 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 15 min 28 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 min 60 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 s 300 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 30 s 80 A
      for 0.1 s 140 A
      for 1 s 100 A
    • Maximum Breaking Capacity:
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
    • Maximum Electrical Switching Frequency:
      AC-1 600 cycles per hour
      AC-15 1200 cycles per hour
      AC-3 1200 cycles per hour
      DC-13 900 cycles per hour
    • Rated Operational Current DC-13 (Ie):
      (110 V) 1.1 A / 121 W
      (220 V) 0.55 A / 121 W
      (400 V) 2.8 A / 134 W
      (500 V) 2 A / 144 W
      (125 V) 1.1 A / 138 W
      (24 V) 6 A / 144 W
      (250 V) 0.55 A / 138 W
    • Maximum Mechanical Switching Frequency:
      3600 cycles per hour
    • Rated Control Circuit Voltage (Uc):
      50 Hz 220 ... 230 V
      60 Hz 230 ... 240 V
  • Climatic Withstand:
    acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible:
    3000 m

Similar products

CUSTOMER REVIEWS

Customer Reviews on ABB AX18-30-01-80 3 Poles Contactor, 1SBL921074R8001

0

There are no customer reviews yet.

Share Your Thoughts With Other Customers

Rate the Product

CUSTOMER QUESTIONS & ANSWERS

Typical questions asked about products:

- Is the item durable?

- Is this item easy to use?

- What are the dimensions of this item?