Key features

  • Rated Insulation Volatge: Acc. to UL/CSA: 600 V.
  • Acc. to IEC 60947-4-1 & VDE 0110 (Gr. C): 1000 V.
  • Rated Impulse Withstand Voltage: 8 KV.
  • Degree of Protection: Acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20.
  • Acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00.

Product Specifications

BrandABB
Warranty

1 Year

Part Number

1SFL637001R7111

Number of Phases

3 Phase

Terminal Type

Main Circuit: Bars

Dimensions

21x24.2x28.3 cm

Weight

15000 g

Ambient Temperature

Close to Contactor Fitted with Thermal O/L Relay (0.85 - 1.1 Uc) -25 to +50deg C

Close to Contactor without Thermal O/L Relay (0.85 - 1.1 Uc) -40 to +70deg C

Close to Contactor for Storage -40 to +70deg C

Operating Time

Between Coil Energization and NO Contact Closing: 50 to 120 ms

Between Coil De-Energization and NO Contact Opening: 53 to 73 ms

Between Coil De-Energization and NC Contact Closing: 50 to 70 ms

Between Coil Energization and NC Contact Opening: 45 to 115 ms

EAN

7320500254851

Operating Voltage

Main Circuit: 1000 V

Frequency

Main Circuit: 50-60 Hz

Number of Contacts

Main Contacts NO: 3

Main Contacts NC: 0

Auxillary Contact

Auxiliary Contacts NO: 1

Auxiliary Contacts NC: 1

Item Code

AF750-30-11-71

Items in Pack

1 Piece

More From ContactorsVIEW ALL

Moglix Guarantees

  • Genuine Products
  • Secure Payment
  • Easy Returns

Product Information

Browse through the extensive list of Contactors at Moglix. Shop online for other ABB Contactors available at Moglix in the lowest price range.

    • Conventional Free-air Thermal Current (Ith):
      acc. to IEC 60947-4-1, Open Contactors q = 40 & 1050 A
    • Rated Operational Current AC-1 (Ie):
      (690 V) 55 & 875 A
      (690 V) 40 & 1050 A
      (1000 V) 40 & 1000 A
      (1000 V) 55 & 875 A
      (690 V) 70 & 720 A
      (1000 V) 70 & 720 A
    • Rated Operational Current AC-3 (Ie):
      (1000 V) 55 & 300 A
      (220 / 230 / 240 V) 55 & 750 A
      (415 V) 55 & 750 A
      (690 V) 55 & 650 A
      (440 V) 55 & 750 A
      (380 / 400 V) 55 & 750 A
      (500 V) 55 & 750 A
    • Rated Operational Power AC-3 (Pe):
      (220 / 230 / 240 V) 220 kW
      (380 / 400 V) 400 kW
      (415 V) 425 kW
      (440 V) 450 kW
      (500 V) 520 kW
      (690 V) 600 kW
      (1000 V) 400 kW
    • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
      8 x Ie AC-3
    • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
      10 x Ie AC-3
    • Short-Circuit Protective Devices:
      gG Type Fuses 1000 A
    • Rated Short-time Withstand Current (Icw):
      at 40 & Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 15 min 1300 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 s 7000 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 min 3500 A
    • Maximum Breaking Capacity:
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
    • Maximum Electrical Switching Frequency:
      AC-3 300 cycles per hour
      AC-1 300 cycles per hour
      AC-2 / AC-4 60 cycles per hour
    • Rated Operational Current DC-1 (Ie):
      (850 V) 3 Poles in Series, 40 & 1050 A
      (600 V) 3 Poles in Series, 40 & 1050 A
      (110 V) 1-Pole, 40 & 1050 A
      (110 V) 2 Poles in Series, 40 & 1050 A
      (220 V) 3 Poles in Series, 40 & 1050 A
    • Rated Operational Current DC-3 (Ie):
      (850 V) 3 Poles in Series, 40 & 1050 A
      (600 V) 3 Poles in Series, 40 & 1050 A
      (110 V) 1-Pole, 40 & 1050 A
      (110 V) 2 Poles in Series, 40 & 1050 A
      (220 V) 3 Poles in Series, 40 & 1050 A
    • Rated Operational Current DC-5 (Ie):
      (850 V) 3 Poles in Series, 40 & 1050 A
      (600 V) 3 Poles in Series, 40 & 1050 A
      (110 V) 1-Pole, 40 & 1050 A
      (110 V) 2 Poles in Series, 40 & 1050 A
      (220 V) 3 Poles in Series, 40 & 1050 A
    • Mechanical Durability:
      3 million
    • Maximum Mechanical Switching Frequency:
      300 cycles per hour
    • Coil Operating Limits:
      (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 &) &
    • Rated Control Circuit Voltage (Uc):
      60 Hz 250 ... 500 V
      50 Hz 250 ... 500 V
      DC Operation 250 ... 500 V
    • Coil Consumption:
      Pull-in at Max. Rated Control Circuit Voltage 60 Hz 985 V·A
      Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A
      Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
      Pull-in at Max. Rated Control Circuit Voltage DC 910 V·A
      Pull-in at Max. Rated Control Circuit Voltage 50 Hz 985 V·A
      Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
    • Connecting Capacity Main Circuit:
      Rigid Al-Cable 300 mm²
      Bar 52 mm
      Rigid Cu-Cable 300 mm²
    • Connecting Capacity Auxiliary Circuit:
      Solid 2 x 1 ... 4 mm²
      Flexible with Insulated Ferrule 2 x 0.75 ... 2.5 mm²
      Stranded 2 x 1 .... 4 mm²
      Flexible 2x0.75 ... 2.5 mm²
      Flexible with Ferrule 2 x 0.75 ... 2.5 mm²

Maximum Operating Altitude Permissible: 3000 m

Similar Products

Entes 16kVAR 440V Capacitor Duty Contactor, ENT-KT-16-C11

29% OFF

₹2,620

₹1,854

  • Brand: Entes

CUSTOMER REVIEWS

Customer Reviews on ABB AF750-30-11-71 3 Phase Contactor, 1SFL637001R7111

0

There are no customer reviews yet.

Share Your Thoughts With Other Customers

Rate the Product

CUSTOMER QUESTIONS & ANSWERS

Typical questions asked about products:

- Is the item durable?

- Is this item easy to use?

- What are the dimensions of this item?