Buy ABB AF65-30-00-14 3 Poles Contactor, 1SBL387001R1400 Online At Best Price On Moglix
ABB AF65-30-00-14 3 Poles Contactor, 1SBL387001R1400

Hover to Zoom

ABB AF65-30-00-14 3 Poles Contactor, 1SBL387001R1400

Check for price and availability.

Available on Request

Key features

  • Rated Insulation Volatge: Acc.to UL/CSA: 600 V.
  • Acc.to IEC 60947-4-1 & VDE 0110 (Gr. C): 690 V.
  • Rated Impulse Withstand Voltage: 6 KV.
  • Degree of Protection: Acc.to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10.
  • Wire Stripping Length Main Circuit: 16 mm.

Product Specifications

BrandABB
Poles

3 Poles

Warranty

1 Year

Part Number

1SBL387001R1400

Terminal Type

Screw Terminals

Dimensions

5.5x11.1x12.55 cm

Weight

950 g

Ambient Temperature

Close to Contactor for Storage -60 to +80 deg C

Close to Contactor Fitted with Thermal O/L Relay -25 to +60 deg C

Close to Contactor without Thermal O/L Relay -40 to +70 deg C

Operating Time

Between Coil De-Energization and NC Contact Closing: 19 to 105 ms

Between Coil De-Energization and NO Contact Opening: 17 to 100 ms

Between Coil Energization and NC Contact Opening: 38 to 95 ms

Between Coil Energization and NO Contact Closing: 42 to 100 ms

EAN

3471523132641

Operating Voltage

Main Circuit: 690 V

Frequency

Main Circuit: 50 -60 Hz

Number of Contacts

Main Contacts NO: 3

Main Contacts NC: 0

Auxillary Contact

Auxiliary Contacts NO: 0

Auxiliary Contacts NC: 0

Item Code

AF65-30-00-14

Items in Pack

1 Piece

RETURN POLICY

Upto 7 days
returnable
Wrong
Product
Damaged
Product
Defective
Product
More From ContactorsVIEW ALL

Moglix Guarantees

  • Genuine Products
  • Secure Payment
  • Easy Returns

Product Information

Browse through the extensive list of Contactors at Moglix. Shop online for other ABB Contactors available at Moglix in the lowest price range.

    • Conventional Free-air Thermal Current (Ith):
      acc. to IEC 60947-4-1, Open Contactors q = 40 & 105 A
    • Rated Operational Current AC-1 (Ie):
      (690 V) 40 & 105 A
      (690 V) 60 & 90 A
      (690 V) 70 & 80 A
    • Rated Operational Current AC-3 (Ie):
      (220 / 230 / 240 V) 60 & 65 A
      (380 / 400 V) 60 & 65 A
      (415 V) 60 & 65 A
      (440 V) 60 & 65 A
      (500 V) 60 & 55 A
      (690 V) 60 & 39 A
    • Rated Operational Power AC-3 (Pe):
      (220 / 230 / 240 V) 18.5 kW
      (380 / 400 V) 30 kW
      (400 V) 30 kW
      (415 V) 37 kW
      (440 V) 37 kW
      (500 V) 37 kW
      (690 V) 37 kW
    • Rated Short-time Withstand Current (Icw):
      at 40 & Ambient Temp, in Free Air, from a Cold State 10 s 600 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 15 min 110 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 min 250 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 30 s 350 A
      for 1 s -empty- A
    • Maximum Breaking Capacity:
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
    • Maximum Electrical Switching Frequency:
      AC-1 600 cycles per hour
      AC-2 / AC-4 150 cycles per hour
      AC-3 1200 cycles per hour
    • Maximum Mechanical Switching Frequency:
      3600 cycles per hour
    • Rated Control Circuit Voltage (Uc):
      50 Hz 250 ... 500 V
      60 Hz 250 ... 500 V
      DC Operation 250 ... 500 V
    • Connecting Capacity Main Circuit:
      Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
      Flexible with Ferrule 1/2x 4 ... 35 mm²
      Rigid 1/2x 6 ... 3 5 mm²
    • Connecting Capacity Control Circuit:
      Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
      Rigid 1/2x 1 ... 2.5 mm²
  • Climatic Withstand:
    Category B according to IEC 60947-1 Annex Q
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    5 ... 300 Hz 3 g closed position / 3 g open position
  • Resistance to Shock acc. to IEC 60068-2-27:
    Closed, Shock Direction: A 25 g
    Closed, Shock Direction: B1 25 g
    Closed, Shock Direction: B2 15 g
    Closed, Shock Direction: C1 25 g
    Closed, Shock Direction: C2 25 g
    Open, Shock Direction: B1 5 g

Similar products

CUSTOMER REVIEWS

Customer Reviews on ABB AF65-30-00-14 3 Poles Contactor, 1SBL387001R1400

0

There are no customer reviews yet.

Share Your Thoughts With Other Customers

Rate the Product

CUSTOMER QUESTIONS & ANSWERS

Typical questions asked about products:

- Is the item durable?

- Is this item easy to use?

- What are the dimensions of this item?