Buy ABB A26-30-10 3 Pole Contactor, 1SBL241001R8610 Online At Best Price On Moglix
ABB A26-30-10 3 Pole Contactor, 1SBL241001R8610

Hover to Zoom

ABB A26-30-10 3 Pole Contactor, 1SBL241001R8610

Check for price and availability.

Available on Request

Product Specifications

BrandABB
Warranty

1 Year

Part Number

1SBL241001R8610

Terminal Type

Screw Terminals

Dimensions

5.4x9.36x9 cm

Weight

600 g

Operating Time

Between Coil Energization and NO Contact Closing: 8-21 ms

Between Coil De-Energization and NO Contact Opening: 4-11 ms

EAN

3471522062864

Operating Voltage

Main Circuit: 690 V

Frequency

Supply Circuit: 50-60 Hz

Number of Poles

3 Pole

Number of Contacts

Main Contacts NC: 3

Main Contacts NO: 0

Auxillary Contact

Auxiliary Contacts NO: 1

Auxiliary Contacts NC: 0

Item Code

A26-30-10

Items in Pack

1 Piece

RETURN POLICY

Upto 7 days
returnable
Wrong
Product
Damaged
Product
Defective
Product
More From ContactorsVIEW ALL

Moglix Guarantees

  • Genuine Products
  • Secure Payment
  • Easy Returns

Product Information

Browse through the extensive list of Contactors at Moglix. Shop online for other ABB Contactors available at Moglix in the lowest price range.

  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 deg C 45 A
    acc. to IEC 60947-5-1, q = 40 deg C 16 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 40 deg C 45 A
    (690 V) 55 deg C 40 A
    (690 V) 70 deg C 32 A
  • Rated Operational Current AC-3 (Ie):
    (220 / 230 / 240 V) 55 deg C 26 A
    (380 / 400 V) 55 deg C 26 A
    (415 V) 55 deg C 26 A
    (440 V) 55 deg C 26 A
    (500 V) 55 deg C 22 A
    (690 V) 55 deg C 17 A
  • Rated Operational Power AC-3 (Pe):
    (220 / 230 / 240 V) 6.5 kW
    (380 / 400 V) 11 kW
    (415 V) 11 kW
    (440 V) 15 kW
    (500 V) 15 kW
    (690 V) 15 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Rated Operational Current AC-15 (Ie):
    (220 / 240 V) 4 A
    (24 / 127 V) 6 A
    (380 / 440 V) 3 A
    (500 V) 2 A
    (690 V) 2 A
  • Short-Circuit Protective Devices:
    Auxiliary Circuit - gG Type Fuses 10 A
    gG Type Fuses 50 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A
  • Maximum Electrical Switching Frequency:
    AC-1 600 cycles per hour
    AC-2 / AC-4 300 cycles per hour
    AC-3 1200 cycles per hour
  • Rated Operational Current DC-13 (Ie):
    (125 V) 1.1 / 138 A
    (24 V) 6 / 144 A
    (250 V) 0.55 / 138 A
    (48 V) 2.8 / 134 A
    (72 V) 2 / 144 A
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Mechanical Durability:
    10 million
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Rated Control Circuit Voltage (Uc):
    50 Hz 400 ... 415 V
    60 Hz 415 ... 440 V
  • Coil Consumption:
    Average Holding Value 50 / 60 Hz 12 V·A
    Average Holding Value 50 / 60 Hz 3 W
    Average Pull-in Value 50 Hz 125 V·A
    Average Pull-in Value 60 Hz 120 V·A
  • Connecting Capacity Main Circuit:
    Flexible with Cable End 0.75 ... 4 mm²
    Rigid Cable 1.5 ... 6 mm²
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Cable End 0.75 ... 2.5 mm²
    Rigid Cable 1 ... 4 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles:
    M 4 (+,-) pozidriv 2 screws with cable clamp

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 deg C
    Close to Contactor for Storage -60 ... +80 deg C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 deg C
    Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 deg C
  • Climatic Withstand:
    acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    Shock Direction: A 20 g
    Closed, Shock Direction: B1 10 g
    Open, Shock Direction: B1 5 g
    Shock Direction: B2 15 g
    Shock Direction: C1 20 g
    Shock Direction: C2 20 g
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Similar products

CUSTOMER REVIEWS

Customer Reviews on ABB A26-30-10 3 Pole Contactor, 1SBL241001R8610

0

There are no customer reviews yet.

Share Your Thoughts With Other Customers

Rate the Product

CUSTOMER QUESTIONS & ANSWERS

Typical questions asked about products:

- Is the item durable?

- Is this item easy to use?

- What are the dimensions of this item?